010-53352947

Magstim NMR-compatible image-guided transcranial magnetic stimulation system

Magstim introduces the new repetitive magnetic stimulation MagstimRapid2 series, which was developed based on extensive consultation with existing clinical and research users. Contact us for more information: 010-53352947

Products

  • Magstim introduces the new repetitive magnetic stimulation MagstimRapid2 series, which was developed in extensive consultation with existing clinical and research users.
  • The Magstim Rapid2 Repetitive Transcranial Magnetic Stimulator (rTMS) is a highly effective non-invasive biphasic magnetic stimulation device that facilitates clinical and academic research.
  • Rapid2 releases a fast, high-intensity pulsed magnetic field that is ideal for bilateral cortical stimulation.
  • Single stimulation, repetitive stimulation, blast stimulation, combined stimulation and many other different stimulation methods can be realized. The unique technology can guarantee the system in
  • It is particularly important to maintain a constant stimulus frequency and stimulus intensity during the release of the stimulus string, which is particularly important for the application of this stimulus.

 

System application:

Magstim Rapid2 is suitable for a wide range of applications.
Cognitive science - for the study of learning ability, memory, language skills, hearing, vision, sensory and functional connections.
Psychiatry - for specific brain functions that affect the dorsolateral prefrontal cortex.
Neurology - for stimulation of peripheral and central nerve pathways.
Rehabilitation medicine - used to promote muscle recovery and the release of nerve tonicity.

Technical considerations:

  • High frequency - Magstim offers stimulation frequencies from 1-50 HZ. The stimulation frequency and output intensity are a pair of parameters that govern each other.
  • Under the same highest 50HZ stimulation frequency, the energy output of different brands varies greatly. The British Magstim 50HZ transcranial magnetic stimulation, has a very high energy/frequency ratio.
  • Channel MEP threshold detection - Magstim offers 2-channel motion threshold module MEP (which is a standard configuration).
  • Safety protection - Magstim 70MM dynamic air-cooled coils, compared with other brands of liquid-cooled coils have high safety (liquid cooling method potential leakage and the risk of leakage), longer service life.
  • Complete System - Magstim magnetic stimulation comes standard with a memory card and micro printer.
  • Navigation - Magstim Magnetic Stimulation is equipped with BrainSight, a professional transcranial magnetic stimulation positioning navigation system.

en_USEnglish